P7360A差分探頭|P7360A的詳細資料:
差分探頭|P7360A
差分探頭|P7360A
- Signal Fidelity
- >12.5 GHz Bandwidth (P7313, Typical)
- >8.0 GHz Bandwidth (P7380A, Typical)
- >6.0 GHz Bandwidth (P7360A, Typical)
- >4.0 GHz Bandwidth (P7340A, Typical)
- Extended Linear Dynamic Range
- 1.25 Vp-p at 5x Attenuation (P7313)
- 4 Vp-p at 25x Attenuation (P7313)
- 2 Vp-p at 5x Attenuation (P7380A, P7360A, P7340A)
- 5 Vp-p at 25x Attenuation (P7380A, P7360A, P7340A)
- Low Probe Loading
- DC Input Resistance
- 100 kΩ Differential
- 50 kΩ Single Ended
- AC Loading
- Zmin >200 Ω out to 10 GHz (P7313)
- Zmin >290 Ω, 4 GHz to 8 GHz (P7380A, P7360A, P7340A)
- DC Input Resistance
- Versatility
- Make Differential or Single-ended (Ground-referenced) Measurements*1
- Solder-down Capability
- Handheld Probing with Variable Spacing and Compliance
- Fixtured Probing
- Interchangeable Tip-Clip™ Assemblies
- Connect to a Variety of Devices
- Economical
- TekConnect® Interface
Applications
- Examples Include, but are not Limited To:
- PCI-Express I and II, Serial ATA II, USB 2.0, DDRII, DDRIII, Fireware 1394b, Rambus, XAUI
*1 For details, please see application note 60W-18344-0, “Making Single-ended Measurements with Differential Probes.”
Z-Active™ Probing Architecture Leads the Way for High-speed Probing Applications
Tektronix has created a revolutionary Z-Active probe architecture that sets the industry benchmark for signal fidelity. Tektronix active probe architecture preserves high bandwidth while providing improved connectivity with low loading. The Z-Active architecture is a hybrid approach composed of a distributed attenuator topology feeding an active probe amplifier.
The Z-Active probes use a tiny passive probe tip element that is separate from the amplifier, extending the usable reach of the probe. In traditional active probes, adding this much length can introduce signal fidelity problems. However this architecture maintains high DC input resistance and presents a higher AC impedance than previous probe architectures. It accomplishes this while providing significant length between the probe body and the probe attachment point to the DUT. This architecture provides the best of both worlds: high DC impedance like existing active probes and the stable high-frequency loading of Z0 probes.
Signal Fidelity
You can be confident in the signal fidelity of your measurements because the Z-Active architecture provides:
- High Bandwidth
- Excellent Step Response
- Low Loading
- High CMRR
- Extended Linear Dynamic Range
Extended Linear Dynamic Range
Many of today’s logic signals and serial bus signals require the capability to measure up to several volts peak to peak. These voltage levels may easily be viewed with the Z-Active architecture probes (P7380A, P7360A, and P7340A) with the extended linear dynamic range. With a 2.0 Vp-p linear dynamic input range at the 5x attenuation setting, you can accuray measure DDR II and III, Firewire 1394b, and PCI-Express I and II signals at reduced noise levels. In addition the 25x attenuation setting’s linear dynamic input voltage range can be used up to 5.0 Vp-p for accessing even larger signal swings found during transition times.
Connectivity
The Z-Active probe design allows the probe to easily switch between soldered, handheld, or fixtured applications.
This family of probes uses Tip-Clip™ assemblies, an interchangeable probe tip system that enables customers to configure their probe with the optimal tip for their application. These detachable assemblies make it possible to replace a tip for a fraction of the cost formerly associated with such hardware changes. The several lengths and variable spacing of the assemblies provide flexibility for adapting to vias and other test points of differing sizes. With Tektronix Tip-Clip assemblies, Monday’s solder-in probe can become Tuesday’s handheld tool, simply by switching tips.
如果你對P7360A差分探頭|P7360A感興趣,想了解更詳細的產(chǎn)品信息,填寫下表直接與廠家聯(lián)系: |